View Full Version : Mini Z - right side has no power?
pajohn
07-29-2006, 12:23 PM
Just happened all of a sudden. The right side will barely move, left side is fine. I checked all the linkage and it looks fine. Bad hydrolic motor or whatever it's called on that side? Anything else to check?
Restrorob
07-29-2006, 01:28 PM
check the hydro. fluid, Belt tension and make sure the pump bypass valve is closed.
MowerMedic77
07-29-2006, 01:49 PM
Also check the bracket that the linkage is attached to at the pump, some manufactures use a set screw to hold that bracket onto the pumps input shaft and they back off and creat play right at the pump.
Fixed many a weak drive system with only an allen wrench:)
pajohn
07-29-2006, 03:00 PM
I got it. There was a nut on the pump that was loose (bypass valve?) I just snugged it up and all is fine. Thanks guys.