PDA

View Full Version : Wright Stander Hydraulics


ferris_1972
10-02-2007, 04:46 PM
Can anyone tell me where the bypass valves are on a 52'' Stander when I have to bleed the system when replacing the hydraulic oil. Thanks

ferris_1972
10-02-2007, 05:16 PM
I am assuming they are the small screws on the side of the pump but just need to make sure.

mcduff48
10-03-2007, 10:55 AM
On the back of each pump there is a valve nut with a screw through it. Turn each counter clockwise one turn to open the by-pass. Make sure you don't take the valve all the way out and when you close it don't "crank down" on it. Just snug it down. You won't distort the valve seat that way. :usflag: