ant
08-24-2009, 09:34 PM
this is like the 4th solenoid. any of u have the same issues?

ant
08-28-2009, 05:38 PM
uppppppppppppppppp

humble1
08-30-2009, 02:49 PM
uppppppppppppppppp

Could be a bad ground or the wire connection are not good, resistance in wire or connection could cause it.

Also sent you a pm

americanlawn
08-30-2009, 03:07 PM
Ditto with humble1. We blew several solenoids on our LESCO Z-two sprayer/spreader. We found that two wires were extremely hot to the touch, so we took it to Sprayer Specialties. Turned out that it had two bad grounds in the wiring harness. Cost us about $300 in labor cuz he had to trace each wire.