liquid limits

Retired now. I was using a sprayer with a 6 gpm pump--Hypro GR232 or maybe 252. I used mostly urea which is a bit safer than Ammonium sulfate, I think.
I used 3/4 pound nitrogen per thousand, above 80 degrees I used a half pound. Above 85 a quarter pound--plus about one-quarter as much potash. Applied about 2.6 gals per thousand sqft.