Indoor Low Voltage Lighting att: James

I need some help regarding installing a low voltage lighting system indoors. I am acting as a consultant in this case. I met some one at my last homeshow who is working on an indoor low voltage project. I told them my specialty is outdoor low voltage lighting and that I am not an expert in indoor low voltage lighting, but I have resources in this area. And that I would like to help them out so that I can get experience in indoor low voltage lighting.

Is there 24v indoor low voltage lighting systems - customer seems to think so? I would think a 12v indoor low voltage system is the easiest to work with. The customer wants 14 puck type fixtures with 35 W lamps, and dimable. I would assume most puck fixtures have a bi-bin lamps. Is there a puck fixture where an MR16 is used? I would assume the easiest lamp regarding being able to buy at stores etc. is the 35 W MR16. The longest homerun will be 40ft. I am assuming we would want to use an electric transformer. What is a good transformer to use in this case? Do these transformers have multi taps? I have basic engineering questions such as, do these electronic transformers have a big voltage drop with a load, In designing these indoor lighting systems what ga. wire do you use for homeruns 12ga.? 10ga.?
Thanks
~Ned
__________________
Ned Hastings
Member AOLP (CLVLT) #0852
www.nightlightingfx.com
Reply With Quote
  #2  
Old 03-04-2009, 04:54 PM
MAGLIGHTING MAGLIGHTING is offline
LawnSite Member
 
Join Date: Feb 2009
Location: Southern California
Posts: 248
Quote:
Originally Posted by NightLightingFX View Post
I need some help regarding installing a low voltage lighting system indoors. I am acting as a consultant in this case. I met some one at my last homeshow who is working on an indoor low voltage project. I told them my specialty is outdoor low voltage lighting and that I am not an expert in indoor low voltage lighting, but I have resources in this area. And that I would like to help them out so that I can get experience in indoor low voltage lighting.


Is there 24v indoor low voltage lighting systems - customer seems to think so? I would think a 12v indoor low voltage system is the easiest to work with. The customer wants 14 puck type fixtures with 35 W lamps, and dimable. I would assume most puck fixtures have a bi-bin lamps. Is there a puck fixture where an MR16 is used? I would assume the easiest lamp regarding being able to buy at stores etc. is the 35 W MR16. The longest homerun will be 40ft. I am assuming we would want to use an electric transformer. What is a good transformer to use in this case? Do these transformers have multi taps? I have basic engineering questions such as, do these electronic transformers have a big voltage drop with a load, In designing these indoor lighting systems what ga. wire do you use for homeruns 12ga.? 10ga.?
Thanks
~Ned

Before you do anything check with your insurance company for coverage, the city for proper licensing required and codes, permits etc. Personally I would never use an electronic transformer for this application. Your digital multimeter will not measure voltage or amperage from an electronic trans. Typically EC's use magnetic buck boost transformers inside the home which can do both 12 and 24 volt outputs depending how they are wired, Some have multi taps. I would wire inline fusing on all cable runs as these transformers usually only have thermal protection. MR-16's do not fit in "hockey puck lights". At 35 watts you also need to consider heat issues.


Regarding your dimmer, make sure you choose the proper one for your load. Inductive for magnetic and electronic for electronic trans. They are also derated so a 1,000 watt dimmer is not a 1,000 watt dimmer. Depending how you configure it, it could handle 750 watts max.

Sounds like you don't really know what you're doing with this based upon the questions you are asking so maybe you should proceed with extreme caution. At the very least have a licensed, insured and bonded EC do the actual install. That still leaves you on the hook liability wise as the designer if anything should go wrong.
Reply With Quote
  #3  
Old 03-04-2009, 05:18 PM
JoeyD's Avatar
JoeyD JoeyD is offline
LawnSite Silver Member
 
Join Date: Aug 2007
Location: Escondido, CA
Posts: 2,965
We sold our 24v units to interior lighting installers and designers long before we ever sold them as a system for exterior systems. 24v is commonly used due tot he fact that its amp draw is lower and its voltage range larger which allows for more diasy chain type wiring which is very common in the interior sector...........Our 24v units can help you here Ned!

First you should do as Mike suggested in regards to codes and liscensing requirements before taking anything like this on yourself.
Reply With Quote
  #4  
Old 03-04-2009, 05:18 PM
INTEGRA Bespoke Lighting's Avatar
INTEGRA Bespoke Lighting INTEGRA Bespoke Lighting is offline
LawnSite Gold Member
 
Join Date: Jun 2007
Location: Muskoka, Ontario, Canada
Posts: 3,972
Ned, give me a call at the office to discuss. I got your voicemail today, and I returned your call. TAG! You're It.
__________________
James Solecki
INTEGRA ~ Bespoke Lighting Systems ®
JSLDesign Inc.


www.integralighting.com

www.facebook.com/INTEGRA.Lighting

Affiliations: IESNA, IALD, IDA, AOLP, LO, MBA
Reply With Quote
  #5  
Old 03-04-2009, 05:20 PM
NightLightingFX's Avatar
NightLightingFX NightLightingFX is offline
LawnSite Senior Member
 
Join Date: Feb 2007
Location: Pasco WA
Posts: 581
I don't know what I am doing - That is why I am posting here. I have clarified with the homeowner this is not my expertise. The homeowner has gotten all the permits etc. In fact the inspector told him for his purposes of using puck lights for the application the home owner wants, low voltage lights would be better.

I volunteered what expertise I have regarding low voltage outdoor lighting and the resources that I have (Such as this forum). I have no legal ties because all I am doing is offering an oppinion as a non bias 3rd party. There are not fees involved and I am not doing any labor. This is an opportunity for me to learn more about other applications of low voltage lighting.
~Ned
__________________
Ned Hastings
Member AOLP (CLVLT) #0852
www.nightlightingfx.com
Reply With Quote
  #6  
Old 03-04-2009, 08:20 PM
MAGLIGHTING MAGLIGHTING is offline
LawnSite Member
 
Join Date: Feb 2009
Location: Southern California
Posts: 248
Quote:
Originally Posted by NightLightingFX View Post
I don't know what I am doing - That is why I am posting here. I have clarified with the homeowner this is not my expertise. The homeowner has gotten all the permits etc. In fact the inspector told him for his purposes of using puck lights for the application the home owner wants, low voltage lights would be better.

I volunteered what expertise I have regarding low voltage outdoor lighting and the resources that I have (Such as this forum). I have no legal ties because all I am doing is offering an oppinion as a non bias 3rd party. There are not fees involved and I am not doing any labor. This is an opportunity for me to learn more about other applications of low voltage lighting.
~Ned
What does the homeowner need you for then? You have told them you don't know what you're doing and you are not getting a fee. Don't be so sure that you will not be responsible if something goes wrong if you are giving your opinion which is being translated from third person instruction. Who is doing the actual work? Hopefully not the homeowner. You are working on the inside of a home with electricity where if something bad happens the consequences are potentially so much far severe than in the garden.

I don't get it why take that risk. Ask someone who is currently doing this work in your area if you can observe them doing what they do if you want to learn. Or experiment on a "safe house" like your own or a friend or family member first until you have a better understanding.
Reply With Quote
  #7  
Old 03-04-2009, 09:58 PM
David Gretzmier David Gretzmier is offline
LawnSite Gold Member
 
Join Date: Mar 2001
Location: Fayetteville,AR
Posts: 3,654
I looked into this way back when and this can also get touchy with city code inspectors. In my town and the two surrounding, I am not allowed to run low voltage cable through walls, period. I use a master EC and also by code have to use wire that is the yellow jacketed 10 or 12 guage high voltage solid wire.

I use the mr-16 can lights that you can aim and change out the sockets for low voltage use. I only use the puck lights for task/surface mount close apps mostly like under cabinet lights on kitchen counters. using EC's is also great because they are awesome at pulling wire, cutting drywall for cans and setting switches. I normally spend the day with them helping wire lights and making sure everything is done to 108-11.5 voltage spec, I wire the trans in a garage if possible on an outside wall. I've only done a few jobs like this, in winter a few years back when the ground was frozen. Fun, but working indoors I had to worry about being clean- my shoes, dust from cutting drywall, ladders scuffing floors, rubbing against expensive furniture, etc. It is definetly a different environment.
__________________
freedom
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.com™ - Moose River Media
All times are GMT -4. The time now is 10:25 PM.

Page generated in 0.10434 seconds with 9 queries