blowout lawn sprinklers

what size compressor would I need to blowout my own system? How much psi is needed? thanx
Reply With Quote
  #2  
Old 10-08-2002, 10:45 PM
rvsuper's Avatar
rvsuper rvsuper is offline
Senior Member
 
Join Date: May 2002
Location: Rock Valley, IA
Posts: 930
At least a 10 CFM Compressor. Set the regulator at about 50-55 PSI. Run every zone for about 5 minutes or until no more water is spraying out.
Reply With Quote
  #3  
Old 10-12-2002, 11:59 AM
MLI's Avatar
MLI MLI is online now
LawnSite Senior Member
 
Join Date: Jul 2000
Location: Ma
Posts: 457
thanx for the info...
Reply With Quote
  #4  
Old 10-14-2002, 10:47 AM
DanaMac's Avatar
DanaMac DanaMac is offline
LawnSite Fanatic
 
Join Date: Mar 2002
Location: Somewhere in the state of CO
Posts: 13,096
Honestly. I don't know the size of the compressor I use. Basically it is a tow behind, diesel engine compressor that I get at the rental shop. I do have it set at about 80 psi though. Usually I can blow out 2-3 residential zones at a time and they only need a couple of minutes.
Reply With Quote
  #5  
Old 10-14-2002, 05:27 PM
rvsuper's Avatar
rvsuper rvsuper is offline
Senior Member
 
Join Date: May 2002
Location: Rock Valley, IA
Posts: 930
DanaMac

You have any pics of how you hook up the compressor to the blowout point? I'm looking for a new way do do this. Right now, I blow out a baseball field with a 3" main and I rent a tow behind for that, and I hook up a key to the Rainbird Quick Connect Right after the PVB with the air hose hooked up to the key. Does anyone hook up to the test coc on the backflows?
Reply With Quote
  #6  
Old 10-14-2002, 07:05 PM
HBFOXJr HBFOXJr is offline
LawnSite Bronze Member
 
Join Date: Jul 2001
Location: Southern New Jersey
Posts: 1,700
test cocks

They restrict air too much. Depending on the GPM of the zones the single hook up may marginal.

With that size stuff we double hose and connect.
1. 2 hoses off the compressor to a double connection on the key

or
2. better yet, 2 hoses off the compressor with 2 key hook ups or threaded pipe inlets.

These larger jobs should have the equivalent of a RainBird #44 or #55 QC valve set up.

The common 50-75 ft 3/4" hose lengths really affect performance at the high volumes of air so 2 are much better.

To make an easy 2nd connection anywhere, you can buy snap on PVC saddles that bond up with glue. Very reliable and strong. Get a 3/4" hole saw to cut the hole after installation. Make sure you use a pipe size by 1" female pipe thread snap on "t". Install a pvc plug with teflon paste, no tape or pipe dope after your done.
__________________
Harold
Reply With Quote
  #7  
Old 10-14-2002, 08:35 PM
Ground Master Ground Master is offline
LawnSite Senior Member
 
Join Date: Feb 2002
Location: colorado springs
Posts: 505
Good tip, Harold. I've seen many guys running what looks like 3/8" hose one might use for air tools.

I use a 5hp gas compressor that does a good job of blowing out residential systems. Its not a perfect setup, as occasionally I have to run through a zone twice. I use this setup for systems with a 3/4" water line, which is the majority in colorado springs. I even have an electric hose reel mounted on the truck which makes handling 3/4" hose a snap. I will try and post a pic soon.

I'll set-up my bigger blow-outs (commercial) on the same day and rent a tow behind.
Reply With Quote
  #8  
Old 10-15-2002, 12:03 AM
rvsuper's Avatar
rvsuper rvsuper is offline
Senior Member
 
Join Date: May 2002
Location: Rock Valley, IA
Posts: 930
HAROLD

what do you use for smaller systems i.e. residentials?
Reply With Quote
  #9  
Old 10-15-2002, 11:03 AM
Ground Master Ground Master is offline
LawnSite Senior Member
 
Join Date: Feb 2002
Location: colorado springs
Posts: 505
I've seen recommendations of 10 to 25 cfm for small systems as well as recomendations of 20 to 50 cfm for small systems (systems with a 3/4" mainline into the house).

I've been using a 5hp gas compressor for 10 years or so (10 cfm) with good results. It does have a 20 gallon tank that I charge up to 60 psi and then I open the valve SLOWLY. This has worked well for me, although I have seen that it is not recommended to build up pressure in an air tank. I suppose the sudden rush of air can cause to much heat.......but I think if you can control the flow you can reduce the risk.


I'd like to rent a bigger compressor in the 12 to 13 hp range (25 cfm) to see how well they work for residential systems. I think these units may be a good compromise between a small setup (like mine) and the big tow behind units.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 08:19 AM.

Page generated in 0.08949 seconds with 9 queries