The brass ones will have the same sort of losses a PRV will have, so you need the headroom to work with it.
Reply With Quote
  #12  
Old 08-07-2010, 10:17 PM
greenmonster304's Avatar
greenmonster304 greenmonster304 is online now
LawnSite Silver Member
 
Join Date: Jul 2007
Location: You Know
Posts: 2,538
Quote:
Originally Posted by Mike Leary View Post
Too bad,that would have the real way to go.
had the guy who built the house knew what he was doing he would have but he was a know it all jerk who said "I had them put in a big pump for the geothermal". But he was an idiot because even with the two airhandlers on at once they only use about 14 gpm. He sold the house now the new owners cant sleep with the water hammer and pump cycling. they told me they had to shut it off last night so they could sleep
Reply With Quote
  #13  
Old 08-08-2010, 06:16 PM
Sprinkus's Avatar
Sprinkus Sprinkus is offline
LawnSite Bronze Member
 
Join Date: Dec 2008
Location: San Antonio, TX
Posts: 1,847
Use CSV1Z for 1-25 gpm. The CSV2W does 5-50 gpm.
Make sure and look at both pressure loss charts because they are additive.
I'd probably use the CSV2W for this application, unless the irrigation zones are very small.
Reply With Quote
  #14  
Old 08-08-2010, 08:09 PM
txgrassguy's Avatar
txgrassguy txgrassguy is offline
LawnSite Gold Member
 
Join Date: Jan 2007
Location: south enough that spanish is necessary
Posts: 3,091
I have installed several plastic cycle stop valves and haven't had one leak yet.
The Cla-valve works well with higher volumes too but are also costly.
Pitch the plastic cycle stop with the idea it isn't as costly and is more of an experiment to determine compatibility - or replace the pump with one correctly sized for the application.
I just thought of something else, is there anyway to plumb in a pressure relief valve back to the well? This would temporarily correct the bulk of the water hammer issues.
__________________
Nice Try = You Suck Spelled Differently
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 01:59 AM.

Page generated in 0.06713 seconds with 9 queries