Register free!
Search
 
     

Click for Weather
Reply
 
Thread Tools Display Modes
  #1  
Old 05-19-2011, 09:58 AM
BFuller BFuller is offline
LawnSite Member
 
Join Date: Jul 2009
Location: Fraser Valley, British Columbia
Posts: 42
Compost Tea Brewer

Hi Guys,

I've been playing around with my compost teas for the last few months and am having good results. The residential, detached homes I've marketed to have had good feedback on our products as well.

The problem is my current brewer is a little small for some of our larger sites, say 5-10 acres. My current brewer is a 50 gallon unit with small air pumps etc. I'm currently building a 300 gallon brewer from a used fertilizer storage container and stainless steel brewing components. I'm looking at regenerative blowers to agitate the water and extract the microbes from the castings, etc.

Now, given the fact that I have 300 gallons to agitate. What size blower will I need. I'm looking at units in the 56-98 CFM range. If anyone can tell me if this CFM rating will effectively churn 300 gallons of tea, I'd greatly appreciate it.

Thanks for the time, and for your responses in advance.

Regards,
Barry
bfuller@direct.ca
Reply With Quote
  #2  
Old 05-19-2011, 10:16 AM
phasthound's Avatar
phasthound phasthound is online now
LawnSite Platinum Member
 
Join Date: Jan 2006
Location: Mt. Laurel, NJ
Posts: 4,047
Quote:
Originally Posted by BFuller View Post
Hi Guys,

I've been playing around with my compost teas for the last few months and am having good results. The residential, detached homes I've marketed to have had good feedback on our products as well.

The problem is my current brewer is a little small for some of our larger sites, say 5-10 acres. My current brewer is a 50 gallon unit with small air pumps etc. I'm currently building a 300 gallon brewer from a used fertilizer storage container and stainless steel brewing components. I'm looking at regenerative blowers to agitate the water and extract the microbes from the castings, etc.

Now, given the fact that I have 300 gallons to agitate. What size blower will I need. I'm looking at units in the 56-98 CFM range. If anyone can tell me if this CFM rating will effectively churn 300 gallons of tea, I'd greatly appreciate it.

Thanks for the time, and for your responses in advance.

Regards,
Barry
bfuller@direct.ca
I'm sure your fellow Canuck, Tim Wilson will chime in soon with an answer.
__________________
Barry Draycott

The nation that destroys its soil destroys itself.
Franklin D. Roosevelt
Reply With Quote
  #3  
Old 05-19-2011, 10:26 AM
Tim Wilson Tim Wilson is offline
LawnSite Senior Member
 
Join Date: Jan 2008
Location: British Columbia, Canada
Posts: 797
Hi Barry;

A good formula through testing I've done is 0.08 CFM per gallon or higher for maximum efficacy in dissolved O2,

http://www.microbeorganics.com/#So_Y...ost_Tea_Brewer

I'm also in the Fraser Valley. If you have not already got your blower check the prices on Sweetwaters at aquaticeco.com
Reply With Quote
  #4  
Old 05-19-2011, 11:38 AM
BFuller BFuller is offline
LawnSite Member
 
Join Date: Jul 2009
Location: Fraser Valley, British Columbia
Posts: 42
Hi Guys,

Thanks for the quick replies. This site is a great resource! Now I just have to start giving back via replies and advice when I can help.

Tim, I've found some good, used units in the 56 CFM range. Is it possible to have too much air in the mix? I can get a used 56 CFM unit for $125 out of Bellingham. If it is too much for a 300 gallon brewer perhaps I could put a valve in-line?

I only ask as my math says 24 CFM would do the trick based on 0.08 CFM per gallon.
Reply With Quote
  #5  
Old 05-19-2011, 12:28 PM
Tim Wilson Tim Wilson is offline
LawnSite Senior Member
 
Join Date: Jan 2008
Location: British Columbia, Canada
Posts: 797
Quote:
Originally Posted by BFuller View Post
Hi Guys,

Thanks for the quick replies. This site is a great resource! Now I just have to start giving back via replies and advice when I can help.

Tim, I've found some good, used units in the 56 CFM range. Is it possible to have too much air in the mix? I can get a used 56 CFM unit for $125 out of Bellingham. If it is too much for a 300 gallon brewer perhaps I could put a valve in-line?

I only ask as my math says 24 CFM would do the trick based on 0.08 CFM per gallon.
It is sometimes possible to have too much turbulance but not likely. It is simple to bleed off some air anyway as you have noted.
Reply With Quote
  #6  
Old 05-19-2011, 12:30 PM
Tim Wilson Tim Wilson is offline
LawnSite Senior Member
 
Join Date: Jan 2008
Location: British Columbia, Canada
Posts: 797
also maybe if you expand you can run 2 brewers with one pump or....
Reply With Quote
Reply

Tags
blower , brewer , compost , tea

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts