  #11  
Old 08-15-2011, 06:56 PM
SoCalLandscapeMgmt SoCalLandscapeMgmt is offline
LawnSite Bronze Member
 
Join Date: Sep 2007
Location: So. Cal.
Posts: 1,511
Quote:
Originally Posted by rlitman View Post
Actually MOV has a much faster reaction time and significantly lower clamping voltage than GDT.
I stand corrected..... I must have misunderstood the info that I was given. I had an EE working for me at one point who was designing an "intelligent" output board to provide the controller with protection from any type of field damage. He seemed to indicate that the GDT and Choke setup had a faster clamping rate..... Of course that was 3 or 4 years ago so I may have remembered wrong!
Reply With Quote
  #12  
Old 08-16-2011, 02:35 PM
regularguy's Avatar
regularguy regularguy is offline
LawnSite Member
 
Join Date: Jul 2003
Location: Seneca, Illinois
Posts: 152
Quote:
Originally Posted by SoCalLandscapeMgmt View Post
If you're looking to protect the controller itself I'd start with something like this....

http://www.controltechusa.com/Universal%20Series.html

Have you used this product in the past and if so how are they performing? This company is really proud of their products and the price certainly reflects it. I have had numerous strikes/power surges on my sprinklers and every time the damage is substantial. I have added a whole house surge protector as well as a high end plug in model for the house voltage side and the T manufacturing boards for the low voltage side and that seems to protect the controllers, now the lightning simply destroys the field wiring, 3 cables so far this year.
Reply With Quote
  #13  
Old 08-16-2011, 03:38 PM
AI Inc's Avatar
AI Inc AI Inc is offline
LawnSite Fanatic
 
Join Date: Dec 2007
Location: Southern NH
Posts: 21,653
Thats where the strike is coming from, the field.
__________________
Reply With Quote
  #14  
Old 08-16-2011, 10:06 PM
agrostis agrostis is offline
LawnSite Bronze Member
 
Join Date: Nov 2009
Location: Winston-Salem NC
Posts: 1,706
I have had the most problems from a golf course with a toro NW8000 system.
The field wiring is a giant conductor for electro-magnetic pulses. I have seen a satellite on fire after a thunderstorm. Repair was about 5000 annually from lightning damage. It is now about 50 (not counting fried solenoids) after D+B 120v surge protectors and data line protectors were installed in each satellite. About 300 for each satellite. http://www.dbpowerinc.com/Irrigation...n/default.html
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 12:32 AM.

Page generated in 0.07224 seconds with 9 queries