Bubbler - Water Height

I usually avoid decorative water features, but I had to replace the pump in an urn bubbler for an existing customer. I installed a 500 gph mag drive which, as best that I could determine, is the standard size for this type of water feature. The customer would like the water to have a greater height than the approx 2 -3 " that it presently has.
My question is: Instead of moving up to the next larger size pump (700 gph). could I instead place a cap on the existing 1/2" stand pipe and drill a smaller than 1/2" hole to increase the PSI? How much smaller hole would I need to drill to get about 6" in water height?
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers
Ripples
Aquatic Habitats
Reply With Quote
  #2  
Old 04-15-2012, 12:33 PM
1idejim's Avatar
1idejim 1idejim is offline
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,884
Quote:
Originally Posted by tadpole View Post
I usually avoid decorative water features, but I had to replace the pump in an urn bubbler for an existing customer. I installed a 500 gph mag drive which, as best that I could determine, is the standard size for this type of water feature. The customer would like the water to have a greater height than the approx 2 -3 " that it presently has.
My question is: Instead of moving up to the next larger size pump (700 gph). could I instead place a cap on the existing 1/2" stand pipe and drill a smaller than 1/2" hole to increase the PSI? How much smaller hole would I need to drill to get about 6" in water height?
you could possibly try using a 1/2" extender repair coupling or inside coupling. reverse the extender. this will close the opening to about 3/8" i believe
Attached Images
   
Reply With Quote
  #3  
Old 04-15-2012, 12:38 PM
tadpole's Avatar
tadpole tadpole is offline
LawnSite Bronze Member
 
Join Date: Jun 2008
Location: Pensacola, Florida
Posts: 1,183
Thanks Jim. That may work, if I can find an extender coupling locally.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers
Ripples
Aquatic Habitats
Reply With Quote
  #4  
Old 04-15-2012, 12:50 PM
1idejim's Avatar
1idejim 1idejim is offline
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,884
Quote:
Originally Posted by tadpole View Post
Thanks Jim. That may work, if I can find an extender coupling locally.
most irrigation suppliers can have them next day and they're not that expensive. i stock a few of each size for leak repairs.

if you can' get one contact me, i may have one in the shop and i can mail it to you.
Reply With Quote
  #5  
Old 04-15-2012, 05:18 PM
1idejim's Avatar
1idejim 1idejim is offline
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,884
i have a few 1/2". if you can't find them contact me
Attached Images
     
Reply With Quote
  #6  
Old 04-15-2012, 05:47 PM
tadpole's Avatar
tadpole tadpole is offline
LawnSite Bronze Member
 
Join Date: Jun 2008
Location: Pensacola, Florida
Posts: 1,183
I appreciate the offer, Jim, but wouldn't a 1/2" cap drilled with a 3/8" hole accomplish the same results? You irrigation guys deal with PSI all the time, us Water Feature guys are usually only concerned with Flow Rate.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers
Ripples
Aquatic Habitats
Reply With Quote
  #7  
Old 04-15-2012, 06:17 PM
1idejim's Avatar
1idejim 1idejim is offline
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,884
Quote:
Originally Posted by tadpole View Post
I appreciate the offer, Jim, but wouldn't a 1/2" cap drilled with a 3/8" hole accomplish the same results? You irrigation guys deal with PSI all the time, us Water Feature guys are usually only concerned with Flow Rate.
depends if the cap were flat or convex on the inside. if the cap is convex then you stand a chance of avoiding hydraulic cavitation turbulence. i feel that the smooth surface of the extender and the inch long neck may prevent directional changes that may be undesirable.

i might be making more of this than there is but i am thinking that you want to raise the water column with the least amount of distortion.
Reply With Quote
  #8  
Old 05-17-2012, 05:07 PM
Ric's Avatar
Ric Ric is offline
LawnSite Fanatic
 
Join Date: Sep 2001
Location: S W Florida
Posts: 11,093
.


Are you sure restricting flow will increase the PSI the desired amount?? This will work on a POSITIVE displacement pump. However most of these submersible pond pumps are CENTRIFUGAL and are limited in PSI but not GPM.

Remember the GPM rating on Pumps is OPEN FLOW with NO back pressure. Add just a touch of back pressure and Flow can drop by half very quick. My point being Do you have the Right pump??

At the price of a Screw on PVC Cap I would buy several. Of course I would Drill each different sizes. By installing a slip to IP thread you can quickly change caps until you find the correct size.

BTW I have made my own fountain nozzles with multiply sprays with just a PVC cap and a drill. Yes it is a trail and error process.


.
__________________
.

"TG doesn't give a rats ass about being "Responsible" as long as sales/production quotas are met. That's it in a nutshell. A recipe for disaster IMO." Ted Putnam 2/28/14

You can lead a Donkey to water but you can't make the Jackass Drink

"As Americans you have the right to be stupid." John Kerry

"Life is tough, but it's tougher when you're stupid.” John Wayne.
Reply With Quote
  #9  
Old 05-17-2012, 06:11 PM
tadpole's Avatar
tadpole tadpole is offline
LawnSite Bronze Member
 
Join Date: Jun 2008
Location: Pensacola, Florida
Posts: 1,183
The final solution was using a 1/2 inch cap with a 3/8 inch hole drilled dead center. Keywords DEAD CENTER, a little off center and you no longer have a vertical water plume. In this case, the type of pump did not matter. This was a 700 gph mag drive. The 3/8" hole increased the height of the water plume four-fold, which was too high. This was easily corrected by reducing the flow rate.
I would still like to know the formula for determining the effect of flow restriction on PSI. I know there is a formula, engineers have one for everything.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers
Ripples
Aquatic Habitats
Reply With Quote
  #10  
Old 05-17-2012, 11:30 PM
1idejim's Avatar
1idejim 1idejim is offline
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,884
Quote:
Originally Posted by tadpole View Post
The final solution was using a 1/2 inch cap with a 3/8 inch hole drilled dead center. Keywords DEAD CENTER, a little off center and you no longer have a vertical water plume. In this case, the type of pump did not matter. This was a 700 gph mag drive. The 3/8" hole increased the height of the water plume four-fold, which was too high. This was easily corrected by reducing the flow rate.
I would still like to know the formula for determining the effect of flow restriction on PSI. I know there is a formula, engineers have one for everything.
i was sure that extender would have worked. bummer. there is a formula for gpm @ psi static using sized mains but it works on large pipe only i gvess. these gauges are common for use on hydrants for fire depts. see pollard water
Posted via Mobile Device
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.com™ - Moose River Media
All times are GMT -4. The time now is 06:01 AM.

Page generated in 0.08490 seconds with 10 queries