#21
|
||||
|
||||
|
May look to see if your pressure tank is waterlogged, then i would start looking elsewhere. Contact your well guy and get gim to look over the system. My well is 290 feet deep 4" well and puts out 10 gpm at 60 psi. Your well depth and pump/system type determine your gpm/psi.
Posted via Mobile Device |
|
#22
|
|||
|
|||
|
Quote:
The one well we have is around 100 feet which is the norm here in FL. |
|
#23
|
||||
|
||||
|
tie the sprinkler pump into the pressurized side of the system. that way it is boosting pressure instead of making it. sounds like your entire system is hooked up backwards or something.
your water should come out if the well and into a pressure tank and then out to your home. put a "t" on the home side of your pressure tank. and hook your sprinkler pump up to that. This should boost your pressure significantly., there should be nothing hooked up between the tank and your well casing except for the contact points and a gauge.
__________________
Deep South Lawn Service www.deepsouthlawn.com 2003 dodge 2500/ cummins 20' landscape trailer - 6.5x12 landscape trailer 5x10 utility trailer '03 lazer 23/60 ,'05 lazer xs 31/72, 2010 lazer 29/60 '02 metro 14/36 15 shindaiwa handhelds, 3 echo saws 2 stihl fs100rx's, 1 stihl br600 magnum '92 long 2360/6'king kutter w/7.5x18 trailer lawn sprinklers save your grass, fire sprinklers save your -----
|
|
#24
|
||||
|
||||
|
heres a drawing
__________________
Deep South Lawn Service www.deepsouthlawn.com 2003 dodge 2500/ cummins 20' landscape trailer - 6.5x12 landscape trailer 5x10 utility trailer '03 lazer 23/60 ,'05 lazer xs 31/72, 2010 lazer 29/60 '02 metro 14/36 15 shindaiwa handhelds, 3 echo saws 2 stihl fs100rx's, 1 stihl br600 magnum '92 long 2360/6'king kutter w/7.5x18 trailer lawn sprinklers save your grass, fire sprinklers save your -----
|
|
#25
|
||||
|
||||
|
as far as well output, some useful info would be:
well depth well casing diameter depth to pump depth to water pump type and rated GPM 110 or 220 volt direct wire or does it have a capacitor start system type of tank size of piping
__________________
Deep South Lawn Service www.deepsouthlawn.com 2003 dodge 2500/ cummins 20' landscape trailer - 6.5x12 landscape trailer 5x10 utility trailer '03 lazer 23/60 ,'05 lazer xs 31/72, 2010 lazer 29/60 '02 metro 14/36 15 shindaiwa handhelds, 3 echo saws 2 stihl fs100rx's, 1 stihl br600 magnum '92 long 2360/6'king kutter w/7.5x18 trailer lawn sprinklers save your grass, fire sprinklers save your -----
|
|
#26
|
|||
|
|||
|
Quote:
|
|
#27
|
|||
|
|||
|
Just talked to my dentist, he said he does every two years a muriactic acid treatment where he drops some tablets down the well pipe, lets them sit for a day, then runs a hose to clean it out for two hours. his gpm just went from 12-35 after doing it.
|
![]() |