|
#1
|
||||
|
||||
|
Bubbler - Water Height
I usually avoid decorative water features, but I had to replace the pump in an urn bubbler for an existing customer. I installed a 500 gph mag drive which, as best that I could determine, is the standard size for this type of water feature. The customer would like the water to have a greater height than the approx 2 -3 " that it presently has.
My question is: Instead of moving up to the next larger size pump (700 gph). could I instead place a cap on the existing 1/2" stand pipe and drill a smaller than 1/2" hole to increase the PSI? How much smaller hole would I need to drill to get about 6" in water height?
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers Ripples Aquatic Habitats
|
|
#2
|
||||
|
||||
|
Quote:
|
|
#3
|
||||
|
||||
|
Thanks Jim. That may work, if I can find an extender coupling locally.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers Ripples Aquatic Habitats
|
|
#4
|
||||
|
||||
|
Quote:
if you can' get one contact me, i may have one in the shop and i can mail it to you. |
|
#5
|
||||
|
||||
|
i have a few 1/2". if you can't find them contact me
|
|
#6
|
||||
|
||||
|
I appreciate the offer, Jim, but wouldn't a 1/2" cap drilled with a 3/8" hole accomplish the same results? You irrigation guys deal with PSI all the time, us Water Feature guys are usually only concerned with Flow Rate.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers Ripples Aquatic Habitats
|
|
#7
|
||||
|
||||
|
Quote:
i might be making more of this than there is but i am thinking that you want to raise the water column with the least amount of distortion. |
|
#8
|
||||
|
||||
|
.
Are you sure restricting flow will increase the PSI the desired amount?? This will work on a POSITIVE displacement pump. However most of these submersible pond pumps are CENTRIFUGAL and are limited in PSI but not GPM. Remember the GPM rating on Pumps is OPEN FLOW with NO back pressure. Add just a touch of back pressure and Flow can drop by half very quick. My point being Do you have the Right pump?? At the price of a Screw on PVC Cap I would buy several. Of course I would Drill each different sizes. By installing a slip to IP thread you can quickly change caps until you find the correct size. BTW I have made my own fountain nozzles with multiply sprays with just a PVC cap and a drill. Yes it is a trail and error process. .
__________________
. "As Americans you have the right to be stupid." John Kerry "Life is tough, but it's tougher when you're stupid.” John Wayne. |
|
#9
|
||||
|
||||
|
The final solution was using a 1/2 inch cap with a 3/8 inch hole drilled dead center. Keywords DEAD CENTER, a little off center and you no longer have a vertical water plume. In this case, the type of pump did not matter. This was a 700 gph mag drive. The 3/8" hole increased the height of the water plume four-fold, which was too high. This was easily corrected by reducing the flow rate.
I would still like to know the formula for determining the effect of flow restriction on PSI. I know there is a formula, engineers have one for everything.
__________________
"Everybody is ignorant, only on different subjects." - Will Rogers Ripples Aquatic Habitats
|
|
#10
|
||||
|
||||
|
Quote:
Posted via Mobile Device |
![]() |
| Bookmarks |
«
Previous Thread
|
Next Thread
»
| Thread Tools | |
| Display Modes | |
|
|
















Linear Mode
