Register free!
Search
 
     

Click for Weather
 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
  #11  
Old 07-07-2012, 11:59 AM
bcg bcg is offline
LawnSite Bronze Member
 
Join Date: Mar 2005
Location: Tx
Posts: 1,770
Quote:
Originally Posted by greenmonster304 View Post
I think your mistake was taking a gpm measurement and a static pressure reading and not a dynamic pressure reading while doing your flow test.

If you have the pressure and flow there is mo reason you can't get 40' out of a # 6 nozzle with funny pipe and saddle tees, I do it all the time.
Posted via Mobile Device
What he said, if you've got 50PSI static, you do not have anywhere near that dynamic. I'd bet your dynamic reading is more like 35PSI or less (just a rough guess). You need to run the math on the hydraulics and figure out what your supply really is or how much you need to increase your pipe sizes.

The funny pipe swing joint isn't the problem.

Last edited by bcg; 07-07-2012 at 12:06 PM.
 

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 02:04 PM.

Page generated in 0.23060 seconds with 9 queries