Way high PSI woes

So one of my apartments (first year contract for me, 15 yr old property) had 135/140 psi at the backflow. Soon as I realized this I immediately put in a request for a pressure regulator. Bid was approved and installed.
Prior to this we'd get leaks and breaks that were pretty obvious it was from high PSI water hammer on the lines.



Now that the regulator has been in I'm changing out A LOT of formerly working heads. 2 cases of RB 5000s and counting, in just one month.
Whats the deal with this? Any body else run into a similar situation?


The best I can come up with as to why they were working and now they aren't is from my help. He wondered if the pressure was so high that it forced a lot of sand/grit past the filters and even tho it was gumming up the works the super high pressure kept the heads working. Now that the pressure is back to more manageable levels the heads just won't work.


Thoughts????????
__________________
Professionals are people who can do their job when they don't feel like it.
Amateurs are people that can't do their job even when they do feel like it.
Reply With Quote
  #2  
Old 09-01-2012, 01:05 PM
Wet_Boots's Avatar
Wet_Boots Wet_Boots is online now
LawnSite Fanatic
 
Join Date: Mar 2005
Location: metro NYC
Posts: 39,810
What nozzle pressures are seen at the bad heads?
Reply With Quote
  #3  
Old 09-01-2012, 01:10 PM
BPS##'s Avatar
BPS## BPS## is offline
LawnSite Senior Member
 
Join Date: Aug 2011
Location: WY
Posts: 822
I should have known you'd ask that. I don't know.

More than enough to push the spring up and spit water the same distance as heads beside them that are working.
A pinched swing line going to the head doesn't make sense on 40 some heads.


This is not a problem on one or two zones that the all the heads don't work. Its across the entire 180,000 sq ft.
__________________
Professionals are people who can do their job when they don't feel like it.
Amateurs are people that can't do their job even when they do feel like it.
Reply With Quote
  #4  
Old 09-01-2012, 01:18 PM
Wet_Boots's Avatar
Wet_Boots Wet_Boots is online now
LawnSite Fanatic
 
Join Date: Mar 2005
Location: metro NYC
Posts: 39,810
Buy a pitot adapter for a pressure gauge. Take some measurements before applying any system remedies.
Reply With Quote
  #5  
Old 09-01-2012, 07:01 PM
CAPT Stream Rotar's Avatar
CAPT Stream Rotar CAPT Stream Rotar is offline
LawnSite Fanatic
 
Join Date: Apr 2007
Location: Cape Cod, Ma
Posts: 5,466
flow control valves?
Reply With Quote
  #6  
Old 09-01-2012, 07:14 PM
Wet_Boots's Avatar
Wet_Boots Wet_Boots is online now
LawnSite Fanatic
 
Join Date: Mar 2005
Location: metro NYC
Posts: 39,810
All rotor heads have bearings, and high pressure can't be any great benefit to them. Maybe overpressure wears bearings, and increases bearing friction. Reducing pressure would then reduce the forces that rotate the head, possibly to a point of non-rotation.
Reply With Quote
  #7  
Old 09-01-2012, 07:18 PM
CAPT Stream Rotar's Avatar
CAPT Stream Rotar CAPT Stream Rotar is offline
LawnSite Fanatic
 
Join Date: Apr 2007
Location: Cape Cod, Ma
Posts: 5,466
I'm on a few systems with 70+ psi and every year we are changing 10 + pgp's..

Pita
Reply With Quote
  #8  
Old 09-01-2012, 07:39 PM
Mike Leary's Avatar
Mike Leary Mike Leary is offline
LawnSite Fanatic
 
Join Date: Mar 2007
Location: Winnemucca, Nevada
Posts: 20,578
Quote:
Originally Posted by Wet_Boots View Post
All rotor heads have bearings, and high pressure can't be any great benefit to them. Maybe overpressure wears bearings, and increases bearing friction. Reducing pressure would then reduce the forces that rotate the head, possibly to a point of non-rotation.
I'm sorta leaning that way. The high pressure wore the original bearings out, and ,when the the pressure was reduced, guess what? The system was over- zoned and failed. I have no problems with rotors at 90 psi, but the design must reflect it.
Reply With Quote
  #9  
Old 09-02-2012, 08:40 AM
AI Inc's Avatar
AI Inc AI Inc is online now
LawnSite Fanatic
 
Join Date: Dec 2007
Location: Southern NH
Posts: 21,478
The system was designed around what was there. Now that psi is reduced it is prolly below working pressure in some areas.
__________________
Reply With Quote
  #10  
Old 09-02-2012, 07:21 PM
Irrigation Contractor Irrigation Contractor is offline
LawnSite Senior Member
 
Join Date: Nov 2011
Location: South East
Posts: 265
Quote:
Originally Posted by BPS## View Post
So one of my apartments (first year contract for me, 15 yr old property) had 135/140 psi at the backflow. Soon as I realized this I immediately put in a request for a pressure regulator. Bid was approved and installed.
Prior to this we'd get leaks and breaks that were pretty obvious it was from high PSI water hammer on the lines.



Now that the regulator has been in I'm changing out A LOT of formerly working heads. 2 cases of RB 5000s and counting, in just one month.
Whats the deal with this? Any body else run into a similar situation?


The best I can come up with as to why they were working and now they aren't is from my help. He wondered if the pressure was so high that it forced a lot of sand/grit past the filters and even tho it was gumming up the works the super high pressure kept the heads working. Now that the pressure is back to more manageable levels the heads just won't work.


Thoughts????????
What did you set the PSI at with the new regulator(s)? In your case we would use a Wilkins 600 HR rated for 75 - 125 PSI and knock it down to 85 or 90.

We have a maintenance project that is very close to what you have going on. We can run 1 or 2 zones at a time with no trouble, the we need to run 3 - 4 to meet the managers (Multi- Family Community) water window expectations.

We still blow mainlines, but now it is due to try to push more gallons through a mainline never designed to handle that amount. I have been telling then we need another water source, then isolate the entire property into 3 smaller systems. This way we can drop the pressure down into the 80's.

Good luck and I know how frustrating it can be, but the best way to cover yourself is with great communication and data to back it up.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 10:15 AM.

Page generated in 0.07599 seconds with 9 queries