Register free!

Reply
 
Thread Tools   Display Modes
  #1  
Old 10-25-2012, 08:17 PM
greenmonster304's Avatar
greenmonster304 greenmonster304 is online now
LawnSite Silver Member
 
Join Date: Jul 2007
Location: You Know
Posts: 2,496
started new project today

started this place today. 3.5-4 acre home with 2 hp sub producing 40 gpm+. 2" pvc main, hunter dual 2 wire. i will post more pics as the job progresses.

https://maps.google.com/maps?q=9+Hol...ork+11976&z=19
Attached Images
     
Reply With Quote
  #2  
Old 10-25-2012, 08:59 PM
Without A Drought Without A Drought is online now
LawnSite Senior Member
 
Join Date: Jul 2006
Location: New Jersey
Posts: 850
i like the dual.
had a few hiccups but nothing too crazy.
definitely get the handheld programmer. it makes things a ton easier
Reply With Quote
  #3  
Old 10-25-2012, 10:30 PM
Sprinkus's Avatar
Sprinkus Sprinkus is offline
LawnSite Bronze Member
 
Join Date: Dec 2008
Location: San Antonio, TX
Posts: 1,837
For those familiar with 2-wire systems:
Found an old Huhnterr IDS 2-wire module while poking through some old stuff the other day. Interestingly enough it had "Made In Denmark" on it.
Reply With Quote
  #4  
Old 10-26-2012, 12:48 AM
SoCalLandscapeMgmt SoCalLandscapeMgmt is online now
LawnSite Bronze Member
 
Join Date: Sep 2007
Location: So. Cal.
Posts: 1,527
Quote:
Originally Posted by Sprinkus View Post
For those familiar with 2-wire systems:
Found an old Huhnterr IDS 2-wire module while poking through some old stuff the other day. Interestingly enough it had "Made In Denmark" on it.
There is a company in Denmark who makes all of the decoders for Rain Bird, Tucor and I guess Hunter as well.
Reply With Quote
  #5  
Old 10-26-2012, 12:53 AM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,988
What is inside of a decoder?
Posted via Mobile Device
Reply With Quote
  #6  
Old 10-26-2012, 07:15 AM
Wet_Boots's Avatar
Wet_Boots Wet_Boots is online now
LawnSite Fanatic
 
Join Date: Mar 2005
Location: metro NYC
Posts: 40,361
Quote:
Originally Posted by 1idejim View Post
What is inside of a decoder?
Posted via Mobile Device
all kinds of neat stuff
Reply With Quote
  #7  
Old 10-26-2012, 09:21 AM
HokieAg07's Avatar
HokieAg07 HokieAg07 is offline
LawnSite Senior Member
 
Join Date: Apr 2006
Location: Richmond, Va
Posts: 352
Quote:
Originally Posted by Sprinkus View Post
For those familiar with 2-wire systems:
Found an old Huhnterr IDS 2-wire module while poking through some old stuff the other day. Interestingly enough it had "Made In Denmark" on it.

IDS = Things nightmares are made of
__________________
Chris
Reply With Quote
  #8  
Old 11-01-2012, 07:54 PM
greenmonster304's Avatar
greenmonster304 greenmonster304 is online now
LawnSite Silver Member
 
Join Date: Jul 2007
Location: You Know
Posts: 2,496
a few more. we finished installing the main and wire today. started the well up and did a flow test, 45 gpm @ 50 psi at the furthest point from the pump. site is still out of power from the storm so had to use my generator to run the pump and controller.
Attached Images
   
Reply With Quote
  #9  
Old 11-01-2012, 08:05 PM
Mike Leary's Avatar
Mike Leary Mike Leary is online now
LawnSite Fanatic
 
Join Date: Mar 2007
Location: Cactus Hug, Arizona
Posts: 20,565
Not bad at all. The loose wire from the clock would have cleaned it up if it was in conduit. Why were sch 80 unions not used on both sides of the p.o.c.? Nice boot shot,M
Reply With Quote
  #10  
Old 11-01-2012, 08:13 PM
greenmonster304's Avatar
greenmonster304 greenmonster304 is online now
LawnSite Silver Member
 
Join Date: Jul 2007
Location: You Know
Posts: 2,496
Quote:
Originally Posted by Mike Leary View Post
Not bad at all. The loose wire from the clock would have cleaned it up if it was in conduit. Why were sch 80 unions not used on both sides of the p.o.c.? Nice boot shot,M
I had to use carflex conduit because the gas line runs horizontal along the building and i couldn't fit rigid conduit behind it so i had to go over it. the 2" stainless union was supplied by the well driller and i didn't see any reason to change it out.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 11:02 PM.

Page generated in 0.07824 seconds with 10 queries