Quote:
Originally Posted by LawnMastersTx View Post

We have looked at the Hunter PRS but they come made with the check valve which does not work with our flow monitoring.
Why is that?
Posted via Mobile Device
Reply With Quote
  #12  
Old 01-22-2013, 01:42 PM
LawnMastersTx's Avatar
LawnMastersTx LawnMastersTx is offline
LawnSite Member
 
Join Date: Jan 2008
Location: Austin, Texas
Posts: 222
Quote:
Originally Posted by 1idejim View Post
Why is that?
Posted via Mobile Device
It does not allow enough flow to go through it to alert our system. We have a threshold of 5 GPM and when a nozzle comes off, the flow is around 7 GPM depending on pressure, but with the check valve, it only becomes 1-2 GPM.
Reply With Quote
  #13  
Old 01-22-2013, 02:05 PM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,993
Quote:
Originally Posted by LawnMastersTx View Post
It does not allow enough flow to go through it to alert our system. We have a threshold of 5 GPM and when a nozzle comes off, the flow is around 7 GPM depending on pressure, but with the check valve, it only becomes 1-2 GPM.
So what you are saying is that you use the flow control to monitor the heads of each zone. You can determine the issue from the control room via historical data?
Posted via Mobile Device
Reply With Quote
  #14  
Old 01-22-2013, 02:50 PM
LawnMastersTx's Avatar
LawnMastersTx LawnMastersTx is offline
LawnSite Member
 
Join Date: Jan 2008
Location: Austin, Texas
Posts: 222
Quote:
Originally Posted by 1idejim View Post
So what you are saying is that you use the flow control to monitor the heads of each zone. You can determine the issue from the control room via historical data?
Posted via Mobile Device

We are using a central irrigation system on campus, Calsense. When a problem occurs at night due to a break, stuck valve, etc., then the system shuts down that zone and alerts me in the morning so I can send my guys to fix it. On average we have 125 high flows at night during a given month.
Reply With Quote
  #15  
Old 01-22-2013, 02:59 PM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 6,993
Quote:
Originally Posted by LawnMastersTx View Post
We are using a central irrigation system on campus, Calsense. When a problem occurs at night due to a break, stuck valve, etc., then the system shuts down that zone and alerts me in the morning so I can send my guys to fix it. On average we have 125 high flows at night during a given month.
That's 4 or more per nite, what's the major reason?

Did you have any input when selecting the system or was it soley the LA's spec?

How do you like Calsense?
Posted via Mobile Device
Reply With Quote
  #16  
Old 01-22-2013, 03:09 PM
LawnMastersTx's Avatar
LawnMastersTx LawnMastersTx is offline
LawnSite Member
 
Join Date: Jan 2008
Location: Austin, Texas
Posts: 222
Quote:
Originally Posted by 1idejim View Post
That's 4 or more per nite, what's the major reason?

Did you have any input when selecting the system or was it soley the LA's spec?

How do you like Calsense?
Posted via Mobile Device
We have a wide range of issues during the night. With 74,000 people on a given day there were broken heads/nozzles. I remember one day testing a zone and watching a student ram his bike into an active head with me standing 15 feet away. I asked him what was going on and he gave me a blank stare. We also have people stealing our nozzles, we use the MP's. Contractors are constantly hitting lines during the day. We also have valves that are over 50 years old still being used so our new system is catching valves that are either sticking on or very slow to turn off.

We have full input on selecting what was going in on campus. At first we were leading towards Rain Master, but once we saw the capabilities of Calsense, we decided on them.

I enjoy the Calsense system and being able to work with it every day. I am a data cruncher and the system gives me plenty of that and reports that I can easily understand. It has helped us discuss the idea with the city on instead of limiting us on the amount of days to water but to give us a budget based off square footage. We have just completed our first year of the trial program and the campus is green with a reduction of overall water use by 51-66% across campus.

The University of Texas does not endorse any product and my views on the materials used are of my own and not from the University.
Reply With Quote
  #17  
Old 01-22-2013, 03:12 PM
Kiril Kiril is offline
LawnSite Fanatic
 
Join Date: Jun 2007
Location: District 9 CA
Posts: 18,316
Quote:
Originally Posted by LawnMastersTx View Post
It does not allow enough flow to go through it to alert our system. We have a threshold of 5 GPM and when a nozzle comes off, the flow is around 7 GPM depending on pressure, but with the check valve, it only becomes 1-2 GPM.
Change your threshold.
Reply With Quote
  #18  
Old 01-22-2013, 03:14 PM
Mike Leary's Avatar
Mike Leary Mike Leary is offline
LawnSite Fanatic
 
Join Date: Mar 2007
Location: Cactus Hug, Arizona
Posts: 20,566
Do you have that way cool Calsense remote?
Reply With Quote
  #19  
Old 01-22-2013, 03:19 PM
LawnMastersTx's Avatar
LawnMastersTx LawnMastersTx is offline
LawnSite Member
 
Join Date: Jan 2008
Location: Austin, Texas
Posts: 222
Quote:
Originally Posted by Kiril View Post
Change your threshold.
I have tried lowering it to the 1-2 GPM, but at night with the fluctuating pressure, I had over 300 high flow alerts.....

Quote:
Originally Posted by Mike Leary View Post
Do you have that way cool Calsense remote?
My techs all use the remote and I use my Ipad or Iphone to control the system.
The remotes have helped them trace down breaks in jasmine beds that they would never have found before. They tally up the GPM based off nozzles/PSI and then check to see what the remote says, if it is not within 2 GPM, they start hunting.
Reply With Quote
  #20  
Old 01-22-2013, 03:28 PM
Kiril Kiril is offline
LawnSite Fanatic
 
Join Date: Jun 2007
Location: District 9 CA
Posts: 18,316
Quote:
Originally Posted by LawnMastersTx View Post
I have tried lowering it to the 1-2 GPM, but at night with the fluctuating pressure, I had over 300 high flow alerts.....
Program around it.

a = average flow
b = current flow
c = % deviation suspend
d = % deviation alert level 1
e = % deviation alert level 2
f = % deviation alert level 3
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 06:03 AM.

Page generated in 0.07174 seconds with 10 queries