pjm123a pjm123a is offline
LawnSite Member
 
Join Date: Jul 2008
Location: FL
Posts: 113
Hydro Leak

Hi All, I have a SCAG Turf Tiger that has a hydro gear BDP 16A-307 pump. The pump has developed a leak around what looks like a plug of some kind. The pump is still on the mower and I m hoping the leak can be fixed without removing it. I have another pump (a different but similar one from a Tiger Cub) from which I have removed this plug to take pictures. There are 2 pics of the plug and a pic of the pump showing where the plug was removed from. Does anybody know what this plug is called? If it is leaking, is it a matter of just replacing it while the pump is still on the mower and just replacing the oil lost? Anybody know where you can order this part and possibly a part number?

Sincere Thanks for any help.
Attached Images
     
Reply With Quote
  #2  
Old 01-26-2013, 10:24 PM
djagusch djagusch is offline
LawnSite Gold Member
 
Join Date: Mar 2006
Location: MN
Posts: 3,440
I think that's a pressure relief valve but could be wrong. I could pull the book out tomorrow and see what they call it. Also in the jthomas catolog's they have a break down of pumps with parts and prices.
Posted via Mobile Device
Reply With Quote
  #3  
Old 01-27-2013, 11:39 AM
BigFish's Avatar
BigFish BigFish is offline
LawnSite Bronze Member
 
Join Date: Jul 2008
Location: chesapeake, va
Posts: 1,633
It's one of a couple of pressure relief/ check valves. That particular one is TOAST!!! You better hope the one ya pull outta your unit is in better shape!! No worries, it will be! Anyways, they use an O-ring seal in the groove just above the threads. Just match it up at an auto parts store that has an O-ring assortment.

Yeah, you should be able to just replace it on the mower. You only need the O-ring.

Hears a link to the Hydro-gear repair manual page. scroll down and click on the link for "pumps" http://www.hydro-gear.com/Main/servi...repair-manuals
__________________
" But let me tell you something ,folks: You can't fix stupid! There's not a pill you can take, there's not a class you can go to. Stupid is forever!"

......AMF!

Last edited by BigFish; 01-27-2013 at 11:47 AM.
Reply With Quote
  #4  
Old 01-27-2013, 06:49 PM
pjm123a pjm123a is offline
LawnSite Member
 
Join Date: Jul 2008
Location: FL
Posts: 113
Hi BigFish. I will try replacing the O-ring. Thanks for your help.
Reply With Quote
  #5  
Old 02-16-2013, 09:32 PM
pjm123a pjm123a is offline
LawnSite Member
 
Join Date: Jul 2008
Location: FL
Posts: 113
Big thanks to BigFish. Today I finally go around to pulling out the valve. Sure enough one side of the o-ring was pretty chewed up. Replaced it and put it back. Did not have to unmount anything and there was only a minimal loss of hydro oil. Buttoned everything back up and ran it a little. So far so good. The real test will come next weekend when I have a fair bit of mowing to to do.
Attached Images
 
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump





Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 02:09 AM.

Page generated in 0.07872 seconds with 10 queries