Try Dultmeier. listed under technical library under plumbing diagrams.

http://www.dultmeier.com/literature.asp
Reply With Quote
  #12  
Old 04-26-2014, 12:04 AM
tebletlawns's Avatar
tebletlawns tebletlawns is offline
LawnSite Member
 
Join Date: Oct 2010
Location: KCMO
Posts: 115
I'm looking at a sprayer with a 3.5 horse Honda motor. Will that be enough to get by for awhile. It has 300 feet of hose. Not sure of the pump yet. It is an older dultmeier sprayer. Thanks for any advice.
__________________
93 Chevy 1/2 ton-260000 miles, motor&trans 15000
18' tandem, custom cage
72" scag turf tiger
48" scag wb
36" scag wb
48" kees wb
fs95 stick edger
2x fs80
2x br600
2x caliced hands
Reply With Quote
  #13  
Old 04-26-2014, 10:05 PM
RigglePLC's Avatar
RigglePLC RigglePLC is online now
LawnSite Fanatic
 
Join Date: Jul 2006
Location: Grand Rapids MI
Posts: 9,429
I am not sure if that is enough power. It should be OK if you are applying solution at about 1 gallon per thousand. Probably less gallons will be available if the hose is smaller--like say a 3/8 instead of half-inch.

Ask the seller if he can get 120 pounds pressure and 2 or maybe 3 gallons per minute at the end of the hose. Remember a 6 gal per minute pump--will only put out about 3 gal per minute--due to friction loss in the 300 ft half-inch hose. 3/8 hose will lose more.
Reply With Quote
  #14  
Old 04-27-2014, 06:44 PM
tebletlawns's Avatar
tebletlawns tebletlawns is offline
LawnSite Member
 
Join Date: Oct 2010
Location: KCMO
Posts: 115
Drove 6 hours round trip to get the sprayer. Got there and it has a 5.5 horse Honda so I'm good. Got home and got it all dialed in at 2 gallons a minute. Thanks for the advice Riggle. What's the best way to rig up temp power supply for the reel until I get the plug for the truck? He's gonna take it if his truck in the next couple weeks.I already have an extra battery.
Posted via Mobile Device
Reply With Quote
  #15  
Old 04-27-2014, 08:53 PM
RigglePLC's Avatar
RigglePLC RigglePLC is online now
LawnSite Fanatic
 
Join Date: Jul 2006
Location: Grand Rapids MI
Posts: 9,429
The fat hot wire from the battery connects to the "B" terminal on the starter relay.
The negative side of the batt usually connects to the frame near the reel motor as a ground.

Not on a trailer, I assume.
Later you will wire the starter relay to the truck battery hot wire--in this case--your truck battery will have the negative connected to ground. You will need a wire to connect your reel motor to the truck frame to close the circuit.
Reply With Quote
  #16  
Old 05-12-2014, 05:41 PM
tebletlawns's Avatar
tebletlawns tebletlawns is offline
LawnSite Member
 
Join Date: Oct 2010
Location: KCMO
Posts: 115
When I am spraying with a decent amount of hose out pressure appears to go up an down. I can see the water flow increase and decrease as the hose gets tugged around. The pressure regulator does not work. Is this the problem. I was able to adjust the agitation and the throttle on the engine to get the pressure and gpm (aprox 90psi @2gpm throttle about a quarter up)I want. But out in the field I'm end up with more left in the tank that I should. I have tried adjusting my speed with no success.
__________________
93 Chevy 1/2 ton-260000 miles, motor&trans 15000
18' tandem, custom cage
72" scag turf tiger
48" scag wb
36" scag wb
48" kees wb
fs95 stick edger
2x fs80
2x br600
2x caliced hands
Reply With Quote
  #17  
Old 05-12-2014, 08:26 PM
RigglePLC's Avatar
RigglePLC RigglePLC is online now
LawnSite Fanatic
 
Join Date: Jul 2006
Location: Grand Rapids MI
Posts: 9,429
Pressure regulator valves sometimes stick; open it all the way to low pressure; spray lube. Crank it down to increase pressure up to about 150. Leave the agitation valve closed until you get enough output flow.

If no success--get a new pressure relief valve--inexpensive. Metal not plastic costs a bit more.
http://www.dultmeier.com/products/search/6588

Last edited by RigglePLC; 05-12-2014 at 08:28 PM. Reason: ps
Reply With Quote
  #18  
Old 05-13-2014, 01:03 AM
greendoctor greendoctor is offline
LawnSite Fanatic
 
Join Date: Mar 2008
Location: Honolulu, Hawaii
Posts: 7,411
My advice is in addition to getting more tank than you think you need to do the same with the pump. To this day, I am kicking myself for not getting a D50 rather than a D30. My tank is not mechanically agitated so there has to be at least 2 GPM available for jet agitation. I also run a 7 nozzle boom for anything too big for me to walk with the 3 nozzle boom. 1 gallon per 1000 is pushing it with the D30.
__________________
They who can give up essential liberty to obtain a little temporary safety, deserve neither liberty nor safety.
Benjamin Franklin 1775

Sell not virtue to purchase wealth, nor Liberty to purchase power.
Benjamin Franklin Poor Richard's Almanac1738
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump





Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 03:26 PM.

Page generated in 0.07794 seconds with 9 queries