Quote:
Originally Posted by Mike Leary View Post
A plastic cycle stop is a good idea, never used one, I know they are cheap. I had no idea it needed to vent. What I always used were: http://cla-val.com
Yeah, they create some back pressure on the pump that will vent out the release valve. It will dump a fair amount of water so you want to put it somewhere that can handle it or you'll end up with a lot of standing water. It can be a pain to find a good spot to drain it to but it is less of a pain than replacing a well pump.

The CSV is about $100 +/-, depending on the size and pressure. If that well pump is cycling from 45PSI - 75PSI, I'd get a 60PSI CSV and nozzle my heads to take full advantage of that.
Reply With Quote
  #32  
Old 07-07-2014, 06:55 PM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 7,031
This is what I use

I'm sure the cyclestops that Bernie is speaking of are actually meant to be installed inside of the well casing. The valves I use do not leak or bypass any water whatsoever.

The op has a problem that's being overlooked guys, rather than suggest quick fixes, he should do or have done a pump down test to tell him his supply, depletion and recharge rates.

If the tank and pressure switch are ok, the only thing left is the pump and conveyance piping. If those are good the mechanical troubles become hydraulic, supply, demand.
Posted via Mobile Device
Reply With Quote
  #33  
Old 07-07-2014, 07:00 PM
bcg bcg is offline
LawnSite Bronze Member
 
Join Date: Mar 2005
Location: Tx
Posts: 1,779
Jim, the CSV isn't what leaks, it's the pressure relief on the well. They do have a version that should be installed in the casing, I use one that is installed outside the casing but it has to be the first thing on the line, before the pressure tank, pressure switch, etc.

I put CSV's on all well systems, even when they're designed for the pump flow. It's cheap insurance.
Reply With Quote
  #34  
Old 07-07-2014, 07:13 PM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 7,031
Quote:
Originally Posted by bcg View Post
Jim, the CSV isn't what leaks, it's the pressure relief on the well. They do have a version that should be installed in the casing, I use one that is installed outside the casing but it has to be the first thing on the line, before the pressure tank, pressure switch, etc.

I put CSV's on all well systems, even when they're designed for the pump flow. It's cheap insurance.
The round plastic ones leaks a bit of water and that's the reason they're meant to be installed inside the casing.

I've installed a (few) of the ones I pictured and a (few) of the psidekicks. Other than the (few) I've installed I don't see a lot of them. I recommended one be installed last Thursday on a well when I was doing a leak detection/repair at this pretty lady's house.

I've never seen any of the brass or bronze valves cause pressure pop offs and I've installed a (few) of them.
Posted via Mobile Device
Reply With Quote
  #35  
Old 07-07-2014, 08:25 PM
greenmonster304's Avatar
greenmonster304 greenmonster304 is online now
LawnSite Silver Member
 
Join Date: Jul 2007
Location: You Know
Posts: 2,533
Quote:
Originally Posted by bcg View Post
Yeah, they create some back pressure on the pump that will vent out the release valve. It will dump a fair amount of water so you want to put it somewhere that can handle it or you'll end up with a lot of standing water. It can be a pain to find a good spot to drain it to but it is less of a pain than replacing a well pump.

Why do you have the relief plumed in between the csv and the pump? Pretty sure the manufacturer doesn't recommend that. This is from their site


Posted via Mobile Device
Reply With Quote
  #36  
Old 07-07-2014, 10:24 PM
bcg bcg is offline
LawnSite Bronze Member
 
Join Date: Mar 2005
Location: Tx
Posts: 1,779
I don't, the well installers do. The relief is on top of the down pipe where that galvanized thread cap is in your picture. I'm not going to move it and risk burning up a pump, I figure the well guys put it there for a reason and if it's draining water, it's probably supposed to.
Reply With Quote
  #37  
Old 07-07-2014, 10:53 PM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 7,031
Quote:
Originally Posted by bcg View Post
I don't, the well installers do. The relief is on top of the down pipe where that galvanized thread cap is in your picture. I'm not going to move it and risk burning up a pump, I figure the well guys put it there for a reason and if it's draining water, it's probably supposed to.
Think about it for a minute.

The relief valve is installed first, before the cycle stop valve and you posted earlier that
Quote:
I use one that is installed outside the casing but it has to be the first thing on the line, before the pressure tank, pressure switch, etc.
So aren't you defeating the purpose of the valve?

I mean, I know it's working for you but it's prolly not working at it's best performance level.
Posted via Mobile Device
Reply With Quote
  #38  
Old 07-08-2014, 10:10 AM
bcg bcg is offline
LawnSite Bronze Member
 
Join Date: Mar 2005
Location: Tx
Posts: 1,779
Jim, I've left them because I believe the CSV is building back pressure on the pump by preventing the tank from getting above the pressure switch cutout point. Those relief valves are set pretty high and I'm concerned that if I remove or plug one, I'll come close to deadheading the pump and cause big problems. If the guy responsible for the well says it's OK to remove it or put it further down the line, I'll do it but I want him to be responsible for any damage, not me. They would be easy to plug or remove, I'm just not willing to risk it. I'd rather deal with some water than the fallout of a dead pump, especially since all of my well systems are on residential properties where the well is also supplying the house water.

I think of it like the air inlet valve for a PVB, if it's venting water, there's probably a good reason for it and you probably want it to be able to do so.
Reply With Quote
  #39  
Old 07-08-2014, 11:01 AM
1idejim's Avatar
1idejim 1idejim is online now
LawnSite Fanatic
 
Join Date: Jul 2009
Location: State of Jefferson
Posts: 7,031
Quote:
Originally Posted by bcg View Post
Jim, I've left them because I believe the CSV is building back pressure on the pump by preventing the tank from getting above the pressure switch cutout point. Those relief valves are set pretty high and I'm concerned that if I remove or plug one, I'll come close to deadheading the pump and cause big problems. If the guy responsible for the well says it's OK to remove it or put it further down the line, I'll do it but I want him to be responsible for any damage, not me. They would be easy to plug or remove, I'm just not willing to risk it. I'd rather deal with some water than the fallout of a dead pump, especially since all of my well systems are on residential properties where the well is also supplying the house water.

I think of it like the air inlet valve for a PVB, if it's venting water, there's probably a good reason for it and you probably want it to be able to do so.
I see your concerns Bernie and you know darn well what I think of your professionalism and intelliect.

I would contact csv and talk to Cary about the issue and the concerns you have though, something just doesn't sound right.
Posted via Mobile Device
Reply With Quote
  #40  
Old 07-08-2014, 11:48 AM
Wet_Boots's Avatar
Wet_Boots Wet_Boots is online now
LawnSite Fanatic
 
Join Date: Mar 2005
Location: metro NYC
Posts: 40,588
The relief would provide some protection for supply lines you fear to over-pressurize.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump






Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©1998 - 2012, LawnSite.comô - Moose River Media
All times are GMT -4. The time now is 08:54 PM.

Page generated in 0.11777 seconds with 9 queries